Study Analyzes Severe Infections in Patients Receiving Left Ventricular
In a detailed ten-year retrospective analysis conducted at Timone University Hospital in Marseille, France, clinical investigators found that more than half of patients supported by durable left ventricular assist devices contracted at least one device-specifi
Illustrative imageIn a detailed ten-year retrospective analysis conducted at Timone University Hospital in Marseille, France, clinical investigators found that more than half of patients supported by durable left ventricular assist devices contracted at least one device-specific infection over the course of their treatment. Mechanical circulatory support devices have become a central therapeutic option for individuals living with advanced end-stage heart failure, serving vital clinical roles as a bridge to heart transplantation, a bridge to candidacy decision-making, a bridge to myocardial recovery, or as lifelong destination therapy. Although iterative technological developments have substantially lowered the frequency of major mechanical issues such as pump thrombosis, infectious complications remain a pervasive clinical challenge, often reaching reported cumulative incidences of up to fifty percent across international cohorts. The enduring vulnerability of these patients stems directly from the anatomical design of modern durable pumps, which rely on an external power source that connects to the intrathoracic pump mechanism via an exit site driveline.
To rigorously examine how infectious episodes develop and influence patient outcomes within a French tertiary referral setting, researchers reviewed the departmental registry of the cardio-thoracic surgery service at Timone University Hospital between January 2014 and March 2024. Four patients were subsequently excluded from the primary analytical dataset due to missing electronic medical records or status as a pediatric minor, leaving an ultimate study population of ninety-three adult patients. Within this analyzed cohort, seventy-eight individuals, representing eighty-three point nine percent of the total, were male, and the cohort presented with a median age of fifty-seven years with an interquartile range spanning fifty to sixty-four years. Prior cardiovascular morbidities were highly prevalent across the group, including a history of smoking in seventy-three point one percent, atrial fibrillation in thirty-four point four percent, systemic hypertension in thirty-three point three percent, obesity in nineteen point four percent, diabetes in seventeen point two percent, and chronic renal failure in eleven point eight percent. Ischemic cardiopathy was identified as the underlying heart failure etiology in fifty-nine point one percent of patients, while non-ischemic cardiomyopathy accounted for forty point nine percent. The contemporary third-generation HeartMate 3 pump was the overwhelmingly dominant hardware configuration, implanted in seventy-one individuals or seventy-six point three percent of the cohort.
Surgical device placements throughout the study decade were executed under uniform aseptic operative conditions according to standardized institutional hospital protocols, which incorporated systematic pre-procedural skin preparation paired with a primary empirical antibiotic prophylaxis regimen consisting of intravenous ceftazidime and linezolid administered over seventy-two post-operative hours. Following hospital discharge, outpatient follow-up occurred through dedicated consultations scheduled every three to six months, complemented by unscheduled emergency admissions and diagnostic reviews whenever emergent medical symptoms emerged. Any suspected infection involving the circulatory support system was submitted to a dedicated multidisciplinary endocarditis team, combining the clinical judgment of an infectious disease specialist, a clinical microbiologist, cardiologists, and cardiac surgeons. Diagnostic classifications strictly implemented the 2024 consensus definitions formulated by the International Society for Heart and Lung Transplantation to differentiate hardware-specific infections from broader non-specific systemic illnesses. Mechanical support-specific events were formally separated into uncomplicated percutaneous lead infections, complicated percutaneous lead infections, device-specific bloodstream infections, device endocarditis, and infections involving the external surfaces of an implantable component. Broader non-specific events, including localized soft-tissue ailments, catheter-related or primary bloodstream events, and systemic sepsis, were concurrently cataloged to construct a complete operational picture of overall pathogen burden, institutional length of stay, and long-term recipient survival.
Over a median duration of mechanical circulatory support of five hundred and sixty-nine days, fifty of the ninety-three patients, corresponding to fifty-three point eight percent, experienced at least one mechanical circulatory support-specific infection. Complicated percutaneous lead infections were diagnosed in twenty-eight individuals, representing thirty point one percent of the cohort, whereas uncomplicated percutaneous lead infections developed in seventeen patients, or eighteen point three percent. Severe deep infections also emerged across follow-up, with device-specific bloodstream infections confirmed in eleven patients, or eleven point eight percent, and infections localized to the external surfaces of the implantable component recorded in ten individuals, or ten point eight percent. In contrast, device-related endocarditis remained exceedingly rare, identified in only a single patient on lifelong destination therapy who presented with late-onset enterococcal bacteremia. Across the entire cohort, recurring infectious episodes raised the total tally of documented specific hardware complications to one hundred and sixty-two distinct events. When evaluating clinical indications for mechanical support, thirty-seven patients had originally received their pump as a bridge to heart transplantation, thirty-one as a bridge to decision, twenty-two as permanent destination therapy, and two as a bridge to recovery, demonstrating that infectious vulnerabilities crossed every therapeutic indication.
The clinical course and diagnostic characteristics of percutaneous lead infections revealed distinct temporal and physiological patterns depending on whether the complication remained uncomplicated or progressed to a deeper complicated state. The majority of lead infections manifested during the first year following implantation surgery, with uncomplicated lead infections emerging after a median delay of two hundred and one days and complicated lead infections developing after a median of one hundred and forty-eight days. Local purulent drainage represented the predominant presenting clinical sign, documented in ninety-four point one percent of uncomplicated episodes and sixty-five point five percent of complicated presentations. However, systemic inflammatory markers and constitutional features diverged sharply between these diagnostic tiers; fever was entirely absent among patients experiencing uncomplicated lead infections but accompanied forty-one point four percent of complicated cases. Median peripheral white blood cell counts were measured at six point four gigaliters in uncomplicated cases compared to eleven point zero gigaliters in complicated infections, while median serum C-reactive protein concentrations rose from eight point three milligrams per liter in uncomplicated presentations to forty-eight point eight milligrams per liter in complicated episodes. In evaluating radiological modalities, fluorine-18 fluorodeoxyglucose positron emission tomography integrated with computed tomography proved highly sensitive, yielding findings directly compatible with infection in eighteen out of twenty examinations, representing a ninety percent diagnostic yield in complicated lead infections.
Deep hardware infections affecting the external surfaces of the implantable components exhibited even more profound clinical toxicity, manifesting at a median delay of two hundred and forty days after mechanical pump implantation. All ten recorded instances of external surface component infections were concurrent with documented device-specific bloodstream infections, and four of these ten events, or forty percent, were preceded by an antecedent percutaneous lead infection. Every patient diagnosed with an external surface component infection presented with fever, while half suffered from overt clinical sepsis accompanied by massive systemic inflammation, evidenced by a median C-reactive protein of two hundred and ninety-four point six milligrams per liter and a median white blood cell count of twenty point three gigaliters. Managing these extensive deep infections necessitated surgical intervention in six of ten presentations, contrasting with surgical revision rates of only ten point three percent for complicated lead infections and five point nine percent for uncomplicated lead infections. Microbial profiling confirmed that Staphylococcus aureus was the overwhelmingly predominant pathogen identified across lead and external surface infections, followed by opportunistic Gram-negative isolates such as Pseudomonas aeruginosa and members of the Enterobacteriaceae family, along with sporadic detections of fungal organisms like Candida albicans.
Beyond hardware-specific infections, non-specific infectious complications afflicted fifty-six of the ninety-three patients, representing sixty point two percent of the overall population, with ninety-four distinct episodes cataloged across the multi-year study window. In striking contrast to the late-onset profile observed with driveline infections, sixty-five of these ninety-four non-specific infections, or sixty-nine point one percent, arose during the initial index hospitalization following implantation surgery, showing a brief median onset delay of only twenty-eight days. These early inpatient complications were predominantly localized bacterial infections, post-operative sepsis, and hospital-acquired non-device bloodstream infections contracted during extended recovery stays in surgical intensive care and cardiothoracic step-down units. The median total initial hospital stay for the surgical cohort spanned forty-eight days, with a median stay in the intensive care unit lasting twenty-two days. Sternal wound infections and mediastinitis occurred in seven patients, or seven point five percent, while two patients experienced infections linked to other cardiac implantable electronic devices. No instances of native or prosthetic valve infective endocarditis were observed. Furthermore, among thirty-one patients who eventually achieved heart transplantation after a median waiting duration of five hundred and eleven days, six individuals, or nineteen point four percent, contracted an early post-transplant infection caused by the identical bacterial pathogen that had colonized their circulatory support hardware prior to transplant surgery.
Detailed sub-analyses evaluating twenty-six patients with percutaneous lead infections specifically caused by Staphylococcus aureus underscored the immense clinical difficulty of eradicating this virulent pathogen with antimicrobial pharmacotherapy alone. Within this microbiological subgroup, eighteen patients suffered from complicated lead infections while eight experienced uncomplicated courses, presenting after a median delay of two hundred and twenty days post-implantation. Methicillin-sensitive Staphylococcus aureus isolates accounted for twenty-five of the twenty-six identified strains, or ninety-six point two percent, whereas methicillin-resistant Staphylococcus aureus was isolated in only one patient. All twenty-six patients received prolonged systemic antimicrobial courses extending beyond two weeks, maintaining a remarkable overall median antibiotic treatment duration of two hundred and seventy-four days. The most frequently prescribed antimicrobial regimens utilized oral trimethoprim-sulfamethoxazole in eighty-four point six percent of patients and fluoroquinolones in forty-six point two percent, alongside clindamycin in twenty-six point nine percent and vancomycin in twenty-three point one percent. Despite this protracted therapeutic exposure, ten patients, or thirty-eight point five percent, suffered a clinical recurrence once antibiotic therapy was discontinued, with three individuals requiring urgent re-hospitalization. Crucially, three patients with Staphylococcus aureus driveline infections, representing eleven point five percent, subsequently demonstrated direct progression to deep external surface pump component infections involving the identical microbial strain, developing between sixty-seven and one thousand and eighteen days after ending treatment.
Throughout the ten-year observation interval, thirty-seven of the ninety-three analyzed patients died, establishing an all-cause cohort mortality of forty point two percent. At the time of biological death, twenty individuals had an active documented infection, representing sixty-two point five percent of the thirty-two deceased patients with complete infectious records available at expiration, while five total deaths, or thirteen point five percent of fatalities, were officially adjudicated to have stemmed directly from an infectious primary cause. In bivariate comparative analyses evaluating fifty patients with device-specific infections, non-surviving patients were significantly older at the time of infection than those who survived, showing a median age of sixty-one point seven years versus fifty-four point four years, an association reaching statistical significance with a p-value of zero point zero forty-seven. Similarly, non-survivors presented with significantly higher baseline peripheral white blood cell counts, displaying a median of thirteen point six gigaliters compared to eight point four gigaliters among survivors, yielding a statistically significant p-value of zero point zero zero four. However, bivariate analyses of the overall cohort demonstrated that neither the presence of hardware-specific infections, nor the accumulation of recurrent infections, was statistically associated with increased all-cause mortality, whereas Kaplan-Meier survival curves indicated an early divergence in survival linked primarily to the rapid onset of severe non-device-related infectious complications during post-operative intensive care stays.
Interpreting these findings requires acknowledging several key methodological and epidemiological boundaries inherent to the study design. Because the research was conducted within a single specialized university hospital center in southern France, local surgical workflows, empirical antimicrobial choices, and diagnostic thresholds may not directly match practice across other international medical centers, though the data provide essential perspective given the historical scarcity of European mechanical circulatory support cohorts. The modest total sample size of ninety-three patients naturally restricted statistical power, preventing the application of robust multivariable regression models to isolate independent risk factors from potential confounding clinical variables. Furthermore, while data were captured using standardized electronic REDCap software from prospective departmental registries, the investigation remained inherently retrospective in structure and did not capture validated patient-reported quality-of-life metrics. Ultimately, the Marseille data confirm that mechanical circulatory support infections represent a persistent double-edged clinical challenge, wherein acute hospital-acquired non-specific infections dominate early post-implantation mortality, while indolent, recurrent hardware-specific infections, led overwhelmingly by Staphylococcus aureus, demand vigilant long-term surveillance and complex multidisciplinary management throughout the life of the device.
Subject of Research: Infectious complications, diagnostic pathways, severity indicators, and mortality among patients receiving durable left ventricular assist devices
Article Title: Infections of left ventricular assist devices: clinical outcomes and mortality
Article References: Prunet, V., Delorme, L., Cortaredona, S., Morera, P., Stolpe, G., & Gouriet, F. (2026). Infections of left ventricular assist devices: clinical outcomes and mortality. JHLT Open, Article 100729. https://doi.org/10.1016/j.jhlto.2026.100729
Image Credits: AI Generated
DOI: 10.1016/j.jhlto.2026.100729
Keywords: Left Ventricular Assist Devices, Mechanical Circulatory Support, Percutaneous Lead Infections, Driveline Infections, Staphylococcus aureus, Timone University Hospital, HeartMate 3, Infectious Complications, Bridge to Transplantation, Destination Therapy, 18F-FDG-PET/CT, Bloodstream Infections, Device Endocarditis, White Blood Cell Count, Prolonged Antibiotic Therapy, Surgical Revision, Sepsis
News Source: Ophelia Keating. (November 23, 2026). Study Analyzes Severe Infections in Patients Receiving Left Ventricular Assist Devices. Scienmag.
