UK Clinicians Strongly Favor On-Body Injectors for Subcutaneous Cancer Drug
A nationwide cross-sectional survey of 162 British healthcare professionals has revealed an overwhelming preference for automated wearable delivery devices over manual needle-and-syringe compounding when preparing large-volume subcutaneous systemic anti-cancer
Illustrative imageA nationwide cross-sectional survey of 162 British healthcare professionals has revealed an overwhelming preference for automated wearable delivery devices over manual needle-and-syringe compounding when preparing large-volume subcutaneous systemic anti-cancer therapies. Published in Frontiers in Oncology, the double-blinded investigation evaluated the anticipated perceptions of 81 hospital pharmacists and 81 oncology nurses across the United Kingdom who routinely prepare complex biologic treatments. When presented with unbranded instructional materials detailing an automated on-body injector alongside current manual syringe protocols, 93.8 percent of all surveyed clinicians—comprising 95.1 percent of pharmacists and 92.6 percent of nurses—favoured the automated device over conventional manual syringes. The research emerges amid documented systemic anti-cancer therapy capacity constraints across the National Health Service, where clinical demand for complex biologic infusions has expanded at annual rates between six and eight percent, creating severe compounding delays, acute workforce pressures, and increasing occupational hazards for preparers in clinical wards and centralized aseptic units.
The study was designed to investigate operational bottlenecks created by the transition from intravenous infusions to subcutaneous formulations of monoclonal antibodies. While subcutaneous co-formulations with hyaluronidase have successfully compressed patient chair administration times by up to 99 percent, they have shifted a considerable compounding burden onto clinical staff. Subcutaneous biologics such as daratumumab, rituximab, trastuzumab, and pertuzumab are viscous, require large-bore needles, and involve multi-step compounding protocols that include vial temperature equilibration, aseptic syringe assembly, viscous biologic withdrawal, needle exchanges, and precise dose priming. Published time-and-motion data highlight that manual syringe preparation requires median durations of 28.1 minutes for subcutaneous daratumumab, 10.8 minutes for rituximab, and 8.7 minutes for trastuzumab. Unlike healthcare delivery systems where compounding remains strictly confined to centralized cleanrooms, the United Kingdom operates a shared model where hospital pharmacy capacity constraints have pushed preparation into acute treatment areas, leaving both hospital pharmacists and frontline nurses heavily exposed to compounding labor.
To capture representative perspectives across this shared delivery landscape, investigators recruited certified practitioners from a third-party healthcare panel between August 14 and August 29, 2025. The final study cohort of 162 clinicians possessed a median of 12 years of clinical practice experience and represented clinical environments across England, Scotland, Wales, and Northern Ireland. Over half of the cohort practised in major teaching hospitals, alongside staff from district general hospitals, specialist tertiary cancer centres, outreach clinics, and homecare teams. All enrolled participants confirmed direct prior experience preparing subcutaneous hyaluronidase-partnered biologics, primarily daratumumab or rituximab, and every participant affirmed direct familiarity with the systemic anti-cancer therapy capacity pressures confronting UK services. Within their everyday institutional environments, 38.3 percent reported that biologic preparation was split across both nursing and pharmacy teams, while 36.4 percent saw preparation handled by pharmacy staff alone, 22.2 percent by nurses alone, and 3.1 percent by pharmacy technicians.
Methodologically, the evaluation utilized a double-blinded cross-sectional design in which the commercial manufacturer of the investigated on-body injector was masked from both survey respondents and administrators, with the device designated neutrally as Product X throughout testing. Because the study captured anticipated perceptions rather than physical usability testing, respondents were oriented through an unbranded 30-second demonstration video and a detailed four-minute narrated technical presentation explaining the closed vial-transfer mechanism. The presented delivery system attaches directly to standard drug vials without manual needle manipulation, automatically filling the wearable injector before patient application. Participants never handled the physical injector, manipulated mock vials, or executed simulated injections. Consequently, all study findings represent structured, anticipated assessments of usability, workflow efficiency, occupational safety, and clinical acceptability derived from standardized educational briefings rather than hands-on human factors measurements or longitudinal clinical practice observations.
Survey assessments revealed high uniform regard for the operational usability and technical learnability of the wearable technology across both clinical disciplines. Following the orientation, 96.9 percent of respondents—including 97.5 percent of pharmacists and 96.3 percent of nurses—judged that the on-body injector appeared easy to use. Similarly, 95.7 percent of the surveyed professionals, reflecting 96.3 percent of pharmacists and 95.1 percent of nurses, anticipated that the automated device would be straightforward to learn. When evaluating broad systemic consequences across hospital cancer clinics, 96.3 percent of respondents agreed that deploying automated injectors across all large-volume subcutaneous biologics would decrease physical and mental workload. Furthermore, 94.4 percent affirmed that the technology would improve hospital efficiency and release clinical capacity, with nurses registering higher perceived significance scores than pharmacists. Additionally, 91.4 percent of participating clinicians believed that shifting away from manual syringe reconstitution would directly decrease preparation errors.
The investigation uncovered distinct professional priorities governing why pharmacists and nurses favoured the automated device. When participants ranked preference drivers in a baseline multiple myeloma treatment scenario retaining standard vial warming, pharmacists prioritized total preparation time, compounding complexity, required supplies, and preparer safety. Conversely, oncology nurses identified preparer physical safety as their leading concern, followed by practitioner manual effort, preparation time, and supply reduction. Across 471 total top-three factor selections in this baseline scenario, active preparation time accounted for 21.2 percent of choices, preparer safety represented 19.7 percent, and healthcare professional effort represented 18.7 percent. When researchers introduced an alternate scenario modeling the theoretical elimination of the lengthy vial-warming step, time savings became the single dominant driver for both professions, capturing 25.6 percent of nurse selections and 21.0 percent of pharmacist choices, lifting overall on-body injector preference to 95.1 percent.
Occupational exposure to contaminated sharps emerged as an acute concern, underscoring the strong safety-oriented preferences recorded among frontline nurses. In total, 87.0 percent of surveyed practitioners—comprising 85.2 percent of pharmacists and 88.9 percent of nurses—reported personal or collegial experience with needlestick injuries sustained during sterile compounding procedures. When asked to define an acceptable operational rate for sharps injuries during sterile reconstitution, nearly half of respondents selected the 1.0 to 2.0 percent category, yielding a weighted mean reasonable threshold of 1.78 percent. In contrast, 96.9 percent of respondents concurred that adopting an automated needle-free vial transfer system would eliminate needlestick hazards entirely during preparation. These observations align with historical surveillance records, such as Public Health England data documenting 8,765 significant occupational exposures between 1997 and 2018, and international economic literature estimating direct and indirect post-exposure management costs at a median of 747 international dollars per incident.
Clinicians also evaluated the suitability of wearable injectors for decentralised cancer care delivery, reflecting NHS strategic efforts to expand home-based treatment. Participating respondents estimated that a weighted mean of 20 percent of oncology biologic administration within their institutions already takes place in home environments through specialised visiting nurses. When evaluating the wearable injector across decentralised scenarios, 96.9 percent considered it suitable for administration by healthcare professionals in home settings, while 95.7 percent rated it suitable for administration by trained family caregivers, and 92.0 percent deemed it suitable for patient self-administration. In qualitative narrative feedback, clinicians highlighted that eliminating complex manual syringe drawing, high backpressure resistance, and open needle manipulation could mitigate the substantial cognitive and logistical burden placed on patients and visiting nurses, potentially unlocking capacity across overbooked hospital infusion suites while maintaining safe oversight.
Economic dimensions surrounding decentralised care also surfaced during qualitative assessments, particularly regarding hospital procurement frameworks and Value-Added Tax regulations. Several clinicians noted that facilitating home administration of cancer biologics could generate institutional cost efficiencies, citing potential 20 percent tax savings through specialized homecare medicine delivery channels where medicines are dispensed directly for self-administration rather than administered as inpatient day-case treatments. However, study authors contextualized these observations, cautioning that Value-Added Tax treatment within the National Health Service depends strictly upon precise contractual configurations, regional procurement mechanisms, and the individual therapeutic agent involved rather than delivering a uniform 20 percent discount. Moreover, researchers underscored that homecare Value-Added Tax rules remain subject to policy scrutiny, pointing to independent fiscal reviews in Scotland that re-examined cost structures and tax relief mechanisms across community distribution models.
The study authors emphasized several structural limitations inherent to the survey design that require cautious interpretation before clinical policy implementation. Because participants were recruited through a closed professional panel using quota-based targets, response rates could not be calculated, and the cohort cannot be considered statistically representative of the wider UK healthcare workforce. Furthermore, respondents received modest financial compensation for survey completion, introducing possible self-report bias. Most crucially, no participant handled, operated, or clinically observed the physical injector, meaning all reported ease-of-use, learnability, safety, and efficiency ratings reflect anticipated attitudes rather than demonstrated operational performance. The investigators stressed that whether these strong practitioner preferences translate into verified clinical improvements, tangible time savings, lower injury rates, or cost-effective outcomes must be confirmed through hands-on human factors evaluations, rigorous time-and-motion studies, and prospective health economic assessments across National Health Service oncology networks.
Subject of Research: Healthcare professional preferences for on-body injectors versus manual syringes in UK subcutaneous cancer biologic preparation
Article Title: Pharmacist and nurse perceptions and preferences for an on-body injector versus manual syringes for large-volume subcutaneous oncology and haematology biologic preparation in the United Kingdom: a cross-sectional survey
Article References: Loughran, C., Miller, H., Senior, R., Quinn, J., DuMond, H., & Desai, M. (2026). Pharmacist and nurse perceptions and preferences for an on-body injector versus manual syringes for large-volume subcutaneous oncology and haematology biologic preparation in the United Kingdom: a cross-sectional survey. Frontiers in Oncology, 16, Article 1958634. https://doi.org/10.3389/fonc.2026.1958634
Image Credits: AI Generated
DOI: 10.3389/fonc.2026.1958634
Keywords: on-body injectors, subcutaneous biologics, systemic anti-cancer therapy, hospital pharmacy, oncology nursing, manual syringe compounding, needlestick injury prevention, daratumumab hyaluronidase, National Health Service, clinical workflow efficiency, aseptic compounding, decentralised cancer care, home administration, multiple myeloma, occupational safety, healthcare workforce burden
News Source: Nathaniel Bowman. (November 25, 2026). UK Clinicians Strongly Favor On-Body Injectors for Subcutaneous Cancer Drug Preparation. Scienmag.